XUCKY Electric is a leading China manufacturer and exporter specializing in ZN12-12 40.5 Series Indoor High Voltage Vacuum Circuit Breaker. We have a wide range of products to meet the different needs of our customers worldwide. Our commitment to superior quality, innovative technology and excellent customer service makes us stand out in our industry.
ZN12-12/40.5 indoor HV vacuum circuit breaker is a 3-phase AC 50Hz 12kV/40.5KV indoor switch equipment.
♦ Installation way: withdrawable type, fixed type;
♦ Operating mechanism: spring ope rating mechanism;
♦ Application: switchgear GBC-35, JYN1-35.
♦ Ambient temperature: -25°C~+40°C;
♦ Altitude: <1000m;
♦ Relative humidity: daily average <95%, monthly average <90%;
♦ Earthquake intensity: <8 level;
♦ Places without fire, explosion hazard, serious filthy, chemical corrosion, as well as intense vibration.
ZN12-12
|
No |
Item |
Unit |
Value |
||||
|
1 |
Rated voltage |
kV |
|
||||
|
2 |
Rated current |
A |
630, 1250, 1600 |
1250, 1600,2000, 2500,3150 |
2000, 2500, 3150,4000 |
||
|
3 |
Rated short circuit breaking current |
kA |
20 |
25 |
31.5 |
40 |
50 |
|
4 |
Dynamic stability current (peak) |
kA |
50 |
63 |
80 |
100 |
125 |
|
5 |
4s thermal stability current |
kA |
20 |
25 |
31.5 |
40/3s |
50/3s |
|
6 |
Rated short circuit making current |
kA |
50 |
63 |
80 |
100 |
125 |
|
7 |
Short circuit current breaking number |
times |
30 |
12 |
|||
|
8 |
Rated operating sequence |
|
CO-0.3S-CO-180S-CO |
O-180S-CO-180S-CO |
|||
|
9 |
Mechanical life |
times |
10000 |
6000 |
|||
|
10 |
Rated current breaking number |
times |
10000 |
6000 |
|||
|
11 |
Rated lightning impulse withstand voltage (full wave) |
kV |
75 |
||||
|
12 |
Rated short time power frequency withstand current (1 min) |
kV |
42 |
||||
|
13 |
Closing time |
ms |
≤75 |
||||
|
14 |
Opening time |
ms |
≤65 |
||||
|
15 |
Power and rated voltage of energy storage motor |
W/V |
275W/ 110V, 220V |
||||
|
16 |
Energy storage time |
s |
<15 |
||||
|
No |
Item |
Unit |
Value |
|
17 |
Rated voltage of closing coil |
V |
110V, 220V |
|
18 |
Rated voltage of opening coil |
V |
|
|
19 |
Rated voltage of interlock coil |
V |
|
|
20 |
Rated current of release |
A |
5 |
|
21 |
Rated current of auxiliary switch |
A |
AC10A, DC5A |
ZN12-40.5
|
No |
Item |
Unit |
Value |
|
|
1 |
Rated voltage |
kV |
40.5 |
|
|
2 |
Rated current |
A |
1250, 1600, 2000 |
1250, 1600,2000,2500 |
|
3 |
Rated short circuit breaking current |
kA |
20, 25 |
31.5 |
|
4 |
Dynamic stability current (peak) |
kA |
50, 63 |
80 |
|
5 |
4s thermal stability current |
kA |
20, 25 |
31.5 |
|
6 |
Rated short circuit making current (peak) |
kA |
50, 63 |
80 |
|
7 |
Short circuit current breaking number |
times |
30 |
20 |
|
8 |
Rated operating sequence |
|
CO-0.3S-CO-180S-CO |
|
|
9 |
Rated lightning impulse withstand voltage (full wave) |
kV |
180 |
|
|
10 |
Rated short time power frequency withstand current (1 min) |
kV |
95 |
|
|
11 |
Closing time |
ms |
≤90 |
|
|
12 |
Opening time |
ms |
≤75 |
|
|
13 |
Mechanica! life |
times |
10000 |
60000 |
|
14 |
Rated current breaking number |
times |
10000 |
60000 |
|
15 |
Rated capacitor bank breaking current |
A |
630 |
|
|
|
Power of energy storage motor |
W |
275 |
|
|
17 |
Rated voltage of energy storage motor |
V |
≃110V, 220V |
|
|
18 |
Energy storage time |
s |
≤15 |
|
|
19 |
Rated voltage of closing and opening coil |
V |
≃110V, 220V |
|
|
20 |
Rated current of overcurrent release |
A |
5 |
|
|
21 |
Rated current of auxiliary switch |
A |
AC10A, DC5A |
|
♦ ZN12-12 (inclined mounted)
Note: dimension 360mm is for current above 2000A, under 2000A, the dimension is 350mm.
Note, in the figure, (215) means when L3=516mm, the dimension is 215mm.
Under 1600A: upper and lower outlet terminal hole 2-M12
Above 2000A: upper and lower outlet terminal hole 4-M12
|
Type |
L |
L1 |
L2 |
L3 |
Remarks |
|
ZN12-12 |
210 |
586 |
610 |
516 |
With inter-phase partition |
|
230 |
620 |
650 |
565 |
||
|
250 |
700 |
740 |
565 |
||
|
275 |
696 |
720 |
516 |
♦ ZN12-12B (flush mounted)(569〈575)
Note: (575) and (364) mean when short circuit breaking current is 40kA or above, the dimensions are 575mm, 364mm.
Upper and lower outlet terminal hole 4-M12
Note: (215) means when L3=516mm; the dimension is 215mm.
|
Type |
L |
L1 |
L2 |
L3 |
|
ZN12-12B |
210 |
586 |
610 |
516 |
|
230 |
620 |
650 |
565 |
|
|
250 |
700 |
740 |
565 |
|
|
275 |
696 |
720 |
516 |
Remarks With inter-phase partition
Address
No.2567 Liuqing South Road, Liushi, Yueqing, Wenzhou, Zhejiang, China
Tel
Claim Your Free quote & sample tailored Solution
Submit an inquiry today along with a competitive quote tailored to your specs.