FZN25-12 Series Indoor High Voltage Vacuum Load Break Switch
Outline
FZN25-12 indoor HV vacuum load break switch a 3-phase AC 50Hz 12kV indoor switch equipment..
♦ Operating mechanism: spring operating mechanism, manual type and electrical type available;
♦ Operation type: right operati on an d left operation;
♦ Operation direction: left operation, right operation;
♦ Application: indoor 12kv switchgear.
Environmental Conditions
♦ Ambient temperature: -25°C 〜+40°C;
♦ Altitude: <1000m (above sea level);
♦ Relative humidity: daily average <95%, monthly average <90%;
♦ Earthquake intensity: <8 level;
♦ Pollution grade: II;
♦ Installation place without fire, explosion, chemical corrosion and serious vibration.
Technical Parameters ♦ Main technical parameters
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1±0.5 |
NO |
Item |
Unit |
FZN25-12D/T 630-20 |
FZRN25-12D/T 200-31.5 |
17 |
Auxiliary circuit rated voltage |
V |
^110 ^220 |
^110 ^220 |
18 |
Earth switch rated short time withstand current |
kA |
20 |
20 |
19 |
Earth switch rated peak short circuit duration |
S |
2 |
2 |
20 |
Earth switch rated peak withstand current |
kA |
50 |
50 |
21 |
Rated short making current |
kA |
50 |
80(prospective peak value) |
22 |
Mechanical life |
times |
10000 |
10000 |
♦ Mechanical property
NO |
Item |
Unit |
Value |
|
FZN25-12 D/ T630 20 |
FZRN25-12 D/T200-31.5 |
|||
1 |
Air clearance between charged parts and to earth |
mm |
>125 |
|
2 |
Conducting tube insert into fixed contact holder depth |
mm |
>18 |
|
3 |
Vacuum interrupter open distance |
mm |
600+1 |
|
4 |
Vacuum interrupter contact spring compression length |
mm |
20+1 |
|
5 |
Vacuum interrupter average closing speed |
m/s |
0.6±0.2 |
|
6 |
Vacuum interrupter average opening speed |
m/s |
1.0±0.2 |
|
7 |
Closing bouncing time |
ms |
<2 |
|
8 |
Three phase closing and opening synchronism |
ms |
<3 |
|
9 |
Main circuit resistance |
rQ |
<150 |
<300 |
10 |
Manual opera+’on maximum torque |
n.m |
<160 |
|
11 |
Fuse trigger opening time |
ms |
- |
30-40 |
12 |
Release trigger opening time |
ms |
40-45 |
♦ Energy storage motor parameters
Model |
Rated voltage V |
Rated current A |
Rated power W |
Normal working voltage range |
LLZY-CJ01B8 |
AC/DC220 |
0.7 |
70 |
85%-110% rated |
66ZY-CJ028 |
AC/DC110 |
1.5 |
voltage |
General Structure Drawing and Installation Size (unit: mm)
♦ FZRN25 right operation

♦ FZRN25 left operation

♦ FZN25 right operation

♦ FZN25 left operation