FN7-12 Series Indoor High Voltage Air Load Break Switch
High quality customized products FN7-12 Series Indoor High Voltage Air Load Break Switch from China suppliers and manufacturers, XUCKY Electric have FN7-12DR type indoor AC off-voltage load break switch is applicable to AC 50Hz, rated voltage 12KV in the three-phase AC power system as a load current breaking and closing short-circuit current use, the combination of electrical appliances can open any current up to short-circuit current, can be used as protection.
FN7-12 is a new type of air indoor high-voltage load break switch. It is suitable for AC 50Hz, rated voltage 12KV three-phase AC power system, as the breaking load current and closing short-circuit current.
Type Description of FN7-12 Series Indoor High Voltage Air Load Break Switch
Working Conditions
● Ambient temperature: -25 °C~ 40°C;
● Altitude: <1000m;
● Relative humidity: daily average <95%; Monthly average <90%;
● There shall be no corrosive, combustion and explosion gas or vapor on the site;
● No frequent violent vibration.
Technical Parameters of FN7-12 Series Indoor High Voltage Air Load Break Switch
Main specifications Note: (-) without (A) with Table 1
Name
Type
Model
DS
DX
L
R
RA
F
Earth switch
at inlet
Earth switch
at outlet
Interlock
device
Fuse
Striker fuse
Electric opening device
Load break switch
Without tripper
FN7-12
-
-
-
-
-
-
FN7-12DSL
A
-
A
-
-
-
FN7-12DXL
-
A
A
-
-
-
FN7-12R
-
-
-
A
-
-
FN7-12DSLR
A
-
A
A
-
-
FN7-12DXLR
-
A
A
A
-
-
With striking tripper
FN7-12RA
-
-
-
-
A
-
FN7-12RAF
-
-
-
-
A
A
FN7-12DXLRA
-
A
A
-
A
-
FN7-12DXLRAF
-
A
A
-
A
A
Rated parameters Table 2
Rated voltage kV
Max. voltage kV
Rated current A
1min power frequency withstand voltage kV
4s thermal stability current(RMS) kA
Dynamic stability current(peak) kA
Short circuit making current kA
Rated breaking current A
Rated transferring current A
12
12
400
42/48
12.5
31.5
31.5
400
1000
630
42/48
20
50
50
630
1000
Rated parameters of fUse Table 3
Model
Rated voltage kV
Rated current A
Rated current of fuse
SDLA*J
12
40
6,3,10,16,20,25,31.5,40
SFLA*J
12
100
50,63,71,80,100
SKLA*J
12
125
125
A*: with striker.
General Structure Drawing and Installation Size ( unit mm )
Drawing 1 FN7-12 load switch outline and installation size
1. Arc Extinguishing Knife 2. Arc Contact Part and Arc Extinguishing Chamber 3. Insulator 4. Base 5. Dynamic Contact Knife 6. Static Contact Knife 7. Spring energy storage device (inside the main axis sleeve) 8. Main knife turning arm
Drawing 2 FN7-12DXL load switch outline and installation size
1.Arc Extinguishing Knife 2.Arc Contact Part and Arc Extinguishing Chamber 3. Insulator 4. Base 5. Dynamic Contact Knife 6. Static Contact Knife 7. Spring energy storage device (inside the main axis sleeve) 8. Earthing Knife 9. Main knife closing turning arm 10. Earthing knife closing turning arm
Drawing 3 FN7-12DXLR separated type load switch outline and installation size
1.Arc Extinguishing Knife 2.Arc Contact Part and Arc Extinguishing Chamber 3. Insulator 4. Earthing knife 5. Base 6. Dynamic Contact Knife 7* Static Contact Knife 8. Fuse 9* Spring energy storage device (inside the main axis sleeve) 10. Earthing energy-storage spring 11. Interlock device 12. Main knife closing&opeing turning arm 13. Earthing knife closing&opening turning arm
Drawing 4 FN7-12R separated type load switch outline and installation size
1.Arc Extinguishing Knife 2.Arc Contact Part and Arc Extinguishing Chamber 3. Insulator 4. Base 5. Dynamic Contact Knife 6. Static Contact Knife 7. Spring energy storage device (inside the main axis sleeve) 8. Fuse 9. Main knife closing&opening turning arm
Drawing 5 FN7-12DXLRA integrated type load switch outline and installation size
1 .Arc Extinguishing Knife 2.Arc Contact Part and Arc Extinguishing Chamber 3. Impact type Fuse 4. Insulator Base 5. Earthing knife 6. Base 7. Dynamic Contact Knife 8. Main knife closing spring 9. Static Contact Knife 10. Earthing energy-storage spring 11. Main knife opening spring 12. Interlock device 13. Main knife closing&opeing turning arm m 14.Earthing knife closing&opening turning arm
Drawing 6 FN7-12C load switch outline and installation size
1.Arc Extinguishing Knife 2. Arc Contact Part and Arc Extinguishing Chamber 3. Insulator 4. Base 5. Dynamic Contact Knife 6. Static Contact Knife 7. Spring energy storage device (inside the main axis sleeve) 8. Plate
Drawing 7 FN7-12CR separated type load switch outline and installation size
1.Arc Extinguishing Knife 2. Arc Contact Part and Arc Extinguishing Chamber 3. Insulator 4. Base 5. Dynamic Contact Knife 6. Static Contact Knife 7. Spring energy storage device (inside the main axis sleeve) 8. Fuse 9. Plate
Drawing 8 FN7-12CDXLRA integrated type load switch outline and installation size
1.Arc Extinguishing Knife 2. Arc Contact Part and Arc Extinguishing Chamber 3. Impact type fuse 4. Earthling knife 5. Insulator 6. Base 7. Main knife closing spring 8. Dynamic Contact Knife 9. Static Contact Knife 10.Earthing energy storage spring 11. Main knife opening spring 12.Plate 13. Drawing 11
Hot Tags: FN7-12 Series Indoor High Voltage Air Load Break Switch, China, Manufacturer, Supplier, Factory
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.
Privacy Policy