BA47-29 series Miniature Circuit breaker(MCB)

Short Description:

Miniature circuit breaker BA47-29 are recommended for use in electrical distribution panels of residential and public buildings.


Product Detail

Product Tags

Introduction

BA47-29  are intended for protecting distribution and group systems having different loads:
- electric appliances, lighting – V characteristic switches;
- drives with moderate starting currents (compressor, fan group) - C characteristic switches;
- drives with high starting currents (hoisting mechanisms, pumps) - D characteristic switches;
Miniature circuit breaker BA47-29 are recommended for use in electrical distribution panels of residential and public buildings.

Advantages

· Two types of short circuit protection.
· Wide range of operating temperatures from –40 to +50° С.
· Updated wider engagement lever with improved contact area.
· Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection.

MCB DA47-29        
For protection of general power distribution (IEC/EN 60898-1)

 

 

 

 

Poles

1P

2P

3P

4P

Electrical performance
Functions

short circuit protection,overload protection,isolationg,control

Rated frequency                        f                               Hz

50-60Hz

Rated working voltage              Ue                         V AC

230/400

400

Rated current                            In                               A

6,10,16,20,25,32,40,50,63

Rated insulated voltage            Ui                  V

500

Impulse withstand voltage          Uimp                kV

4

Instantaneous tripping type

BA47-29

B/C/D

Rated short circuit Icn(kA)       

BA47-29

4.5

Release type  

Thermal magnetic type

Service life(O~C)

Mechanical

 Actual value

20000

 Standard value

4000

Electrical

 Actual value

8000

 Standard value

4000

Connection and installation
Protectiom degree

IP20

Wire                                             mm²

1~35

Working temperature

-5 ~+40℃

Resistance to humidity and heat

Class 2

Altitude above sea

≤2000

Relative humidity

+20℃ , ≤90% ;+40℃ , ≤50%

Pollution degree

2

Installation environment

Avoid obvious shock and vibration

Installation class

Class Ⅱ , Class Ⅲ

Mounting

DIN35 rail

Combination with accessories
Auxiliary contact

Yes

Alarm contact

Yes

Shunt release

Yes

Undervoltage release

Yes

Auxiliary contact+Alarm contact

Yes

Dimensions(mm) 

(WxHxL)                                                    图片1                     

a

17.5

35

52.5

70

b

80.2

80.2

80.2

80.2

c

76.5

76.5

76.5

76.5


  • Previous:
  • Next:

  • Write your message here and send it to us