C65-63 Circuit Breaker (6KA MCBs)

Short Description:

C65-63 6KA Circuit Breaker (also called 6KA Household MCB, similar to CHINT NB1-63) is used for the circuit of AC 50Hz, rated voltage of 110V/230/400V, rated current of 1A, 2A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 60A, 63A to protect overload and short-circuit, as well as use for normal circumstances of the infrequent circuit conversion, also be used as the isolating switch for cut-off circuit to protect circuit and equipment.


Product Detail

Product Tags

Scope of Application

C65-63 6KA Circuit Breaker (also called 6KA Household MCB, similar to CHINT NB1-63) is used for the circuit of AC 50Hz, rated voltage of 110V/230/400V, rated current of 1A, 2A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 60A, 63A to protect overload and short-circuit, as well as use for normal circumstances of the infrequent circuit conversion, also be used as the isolating switch for cut-off circuit to protect circuit and equipment.
6KA Circuit Breaker (6KA Household MCB) are used for industrial, commercial, high-rise and civilian residential and other places.
Meet the standards: GB10963.1, IEC60898-1.

Main Technical Parameters

Rated Current

6A,10A,16A,25A,40A,50A,63A

Poles

1P.2P.3P,4P,1P+N,3P+N

Rated Voltage Ue

230V/400V

Rated Impulse Withstand Voltage(1.2/50)Uimp

6kV

Dielectric Test Voltage At And Ind . Freq . For 1min

6kV

Breaking Indication

Green Window(Disconnected),Red Window(Closed)

Protection Class

IP20

Thermo - Magnetic Release Characteristic

B-Curve (3-5In),C-Curve (5-10In),D-Curve (10-14In)

Electrical Life

2000

Mechanical Life

10000

Reference Temperature For Setting Of Thermal Element

30℃

Ambient Temperature

-5~+40℃

Terminal Connection Type

Phillips Screws

Adapter Cable

6-63A 1-25mm² 16-3AWG | 80-125A 8-35mm² 16-2AWG

Tightening Torque

3.0N.M

Combination With Accessories Auxillary Contact

Auxillary Contact

Yes

Alarm Contact

Yes

Shunt Release

Yes

Under Voltage Release

Yes

Tripping Characteristic Curve -- B C D Type

图片1
图片2
图片3

Temperature compensation

When the ambient temperature is not a benchmark of 30 degrees , the reference correction factor is as folows .

Ambient Temperature

-20℃

-10℃

0℃

10℃

20℃

30℃

40℃

50℃

60℃

Current Correction Coefficient

1.25

1.2

1.15

1.10

1.05

1.00

0.95

0.90

0.85

Connection

Rated Current

Minimum Adapter Copper Wire

6A

1 MM² / 17AWG

10A

1.5 MM² / 16AWG

16A

1.5 MM² / 16AWG

25A

2.5 MM² / 13AWG

32A

4 MM² / 11AWG

   

40A

6 MM² / 10AWG

50A

10 MM² / 7AWG

63A

10 MM² / 7AWG

Mounting Method

Th35-7.5 type steel mounting rail is used for installation.