M11 Series Moulded-case Circuit Breaker

Short Description:

M11, M11LY, M11RT, M11E and M11EL series of circuit breakers are new upgraded circuit breakers researched and developed by the company combined with the advantages of similar international products and demand of domestic and international markets.


Product Detail

Product Tags

Product overview

M11, M11LY, M11RT, M11E and M11EL series of circuit breakers are new upgraded circuit breakers researched and developed by the company combined with the advantages of similar international products and demand of domestic and international markets.
With insulation voltage up to 1000V, the circuit breaker is applicable for distribution systems of AC50Hz, rated working voltage 690V and rated working current from 10A to 800A, used to distribute electric power energy, protect circuits and power equipment against overload, short circuit, under voltage and so on, also can be used for infrequent startup of motor and protect it from overload, short circuit or under voltage.
It is featured with small size, high breaking, short flashover, etc., is the ideal product for users. It can be vertically installed or horizontally installed.
M11DC series DC moulded-case circuit breaker (hereinafter referred to as circuit breaker) is suitable for DC systems of rated voltage up to and including DC 1000V and rated current 10~800A, used to distribute electric power energy, protect circuits and power equipment against overload, short circuit and so on.
The products can be fed with wires from top and bottom, and it is polarity-free.
It complies with the standards IEC60947-2, GB14048.2, etc.

Product features

Feature 1: current limiting capacity
Current-limiting refers to limit of the increase of short-circuit current in the loop, and in the loop protected by M11, peak value of the short-circuit current and the I2t energy in the circuit will be much smaller than the prospective value.

U-shaped fixed contact
Unique U-shaped fixed contact can achieve pre-breaking technology:
The so-called pre-breaking technology refers to when short-circuit current flows through the contact system, electric power generated by U-shaped fixed contact and moving contact is mutual exclusive. The greater the short-circuit current is, the greater the repulsion of the electromotive force, and it is generated together with the short-circuit current at the same time. Before the trip action occurs, the electrodynamic repulsion force can make the fixed and moving contact separation, by increasing the arc to increase the equivalent resistance between them to achieve the purpose of suppressing increase of short-circuit current.

Feature 2: modular accessories
◆ Accessory: For the circuit breakers of the same frame, they has uniform sizes regardless of the breaking capacity and rated current;Accessory: Users can freely 
◆ choose and expand functions of circuit breakers according to their needs
◆ Modular accessories have insulation function, which is easy for hot-line operation and installation.

Feature 3: miniaturized frame
5 frame sizes: 125 type, 160 type, 250 type, 630 type, 800 type
Rated current of M11 series 10A~800A 

图片1

Feature 4: contact repulsion device (patented technology)

The technical scheme adopted by the invention is:
As shown in Figure 1, the new contact device is mainly consisted of fixed contact, moving contact, shaft 1, shaft 2, shaft 3 and springs;
When the circuit breaker is in the closed state, shaft 2 acts on the right side of the spring angle; When the circuit breaker has a large fault current, the moving contact will be subjected to the electric repulsion generated by the current itself, and rotate with the center of shaft 1, when shaft 2 rotates to the top of the spring angle with the moving contact, it makes moving contact to rapidly rotate upwards and quickly break the circuit upon the reaction of spring, it has enhanced the breaking capacity of the product through optimization of the contact structure.

图片2

Feature 5: intelligence
Network communication is more convenient. It accesses to Modbus communication system through dedicated connection. M11E / M11EL with communication function can select monitoring accessories to realize door display, read, set and control.

图片3

Feature: modularized arc extinguishing system 

图片4

Feature 7: unification

The six series of M11, M11LY, M11DC, M11RT, M11E, and M11EL under the same frame size have the same dimensions, installation dimensions and appearance style, which is completely unified design.

Ambient and installation conditions

◆ Altitude up to 2000m;
◆ Ambient medium temperature should be within -5℃ to +40℃ (+45℃ for marine products);
◆ It can withstand the effect of damp air;
◆ It can withstand the effect of moulds;
◆ It can withstand the effect of nuclear radiation;
◆ The max inclination is 22.5℃.
◆ It still can work reliably when the ship subjects to normal vibration;
◆ t can still work reliably if the product subjects to the earthquake (4g).
◆ Places where the surrounding medium is free from explosion danger, and far away  from gas or conductive dust that would erode the metal or destroy the insulation;
◆Keep away from rain or snow.  

Components of circuit breaker

1 Auxiliary switch 5 Terminal cap 9 Manual operation
2 Alarm switch 6 Phase partition 10 Plug-in type back-board wiring
3 Shunt release 7 Front-board wiring 11  Back-board wiring
4 Undervoltage release 8 Electric operation  

图片5

Model selection guide

M11 125 C P 4
Product code Frame size Current class Code of control circuit source voltage Pole number
Moulded-case 125 160 250 400 630 800   C S H P: electric operation 3: 3-pole
circuit breaker Note: 125 10月15日 18/15 28/18 Z: rotary handle 4: 4-pole
  125 is upgraded type of 63 frame 160 20/15 25/18 35/25 W: direct operation  
  160 is upgraded type of 100 frame 250 25/15 25/18 35/25    
  250 is upgraded type of 225 frame 400   35/25 50/35    
  630 is upgraded type of 400 frame 630   35/25   50/35    
    800   50/35 65/50    

 

300

125A

2

A

Release type and internal accessory

Rated current (A)

Application

Code of four-pole product

The first digit represents release type

125

10, 16, 20, 25, 32, 40, 50,63, 80, 100, 125

1: power distribution

A: N-pole without protection cannot close or open

2: Has instantaneous release only

160

63, 80, 100, 125, 140, 160

2: motor protection

B: N-pole without protection can close and open

3: Complex release Note:

250

100, 125, 140, 160,180, 200, 225, 250

 

C: N-pole with protection can close and open

Later two digits are the code of accessories (see accessory table)

400

250, 300, 315, 350, 400

 

D: N-pole with protection cannot close or open

 

630

400, 500, 630

   
 

800

500, 630, 700, 800

   

 

Q1

D1

Q

2

Accessory voltage

Electric operation voltage

Installation methods

Install wiring board or not

Undervoltage release

Shunt release

Auxiliary alarm

DC1 Electric Operation

DC3 Electric Operation

Q: Front-board

1: No

Q1: AC220V

F1: AC220V

J1: AC125V

D1: AC220V

D5: AC230V

H: Back-board

2: Yes

Q2: AC240V

F2: AC380V

J2: AC250V

D2: AC230V

D6: AC110V

C: Plug-in type

 

Q3: AC380V

F3: DC110V

J3: DC125V

D3: AC380V

D7: DC220

   

Q4: AC415V

F4: DC24V

J4: DC24V

D4: AC400V

D8: DC110

   

 

 

 

 

D9: AC110-240V

   

 

 

 

 

D10: DC100-220V

   

 

Note:

   

Adaptable voltages for two electric

   

operations. Please refer to the

   

introduction of external accessory.

   

● Circuit breaker can be equipped with undervoltage release, shunt release, auxiliary contacts, alarm contacts, electric operating mechanism, rotary operating handle and other accessories.
● Circuit breaker has protection functions of overload long delay, short-circuit short delay and short-circuit
instantaneous protection, the user can set the required protection characteristics (user only needs to operate the DIP switch for settings of protection function parameters).
● Circuit breaker has ground fault and thermal analog protection functions, pre-alarm indication over-current
indication, load current indication, digital current analysis technology, and it can achieve a higher level of protection.

M11 thermal overload technical data sheet

 图片6

图片7 

图片8 

图片9 

图片10 

图片11 

Frame current (A)

125

160

250

400

630

800

Model

M11-125C

M11-125S

M11-125H

M11-160C

M11-160S

M11-160H

M11-250C

M11-250S

M11-250H

M11-400S

M11-400H

M11-630S

M11-630H

M11-800S

M11-800H

Pole number

1, 2, 3, 4

2, 3, 4

3, 4

3, 4

3, 4

3, 4

Rated current (A)

10, 16, 20, 32, 25, 40, 50,63, 80, 100, 125

63, 80, 100, 125, 140, 160

100, 125, 140, 160, 180,200, 225, 250

250,315,350,400

250, 315, 350, 400, 500, 630

500, 630, 700, 800,1000,1250

Rated voltage (V)

AC400V

AC400V

AC400V

AC400V

AC400V

AC400V

Rated insulation voltage (V)

AC1000V

AC1000V

AC1000V

AC1000V

AC1000V

AC1000V

Short-circuit breaking capacity(KA)Icu/Ics

AC400V

10/15

18/15

25/18

20/15

25/18

35/25

25/15

25/18

35/25

35/25

50/35

35/25

50/35

50/35

65/65

Operating cycle number

Electrical life

6000

3000

3000

2000

2000

1500

Mechanical life

9000

7000

7000

4000

4000

4000

Outline dim(mm)

1P

25-130-68-90

-

-

-

 

 

 

 

a-b-c-ca

2P

50-130-68-90

60-155-68-90

60-155-88-115

 

 

 

 

 图片17

3P

75-130-68-90

90-155-68-90

90-155-88-115

105-165-68-92

105-165-88-115

140-257-103-155

140-257-103-155

210-275-103-155

4P

100-130-68-90

120-155-68-90

120-155-88-115

140-165-68-92

140-165-88-115

184-257-103-155

184-257-103-155

280-275-103-155

Weight (kg)

1P

0.32

-

-

-

 

 

 

 

 

2P

0.5

0.55

1

1.1

1.5

1.7

5.5

5.7

9.5

3P

0.55

0.65

1.1

1.2

1.9

2.1

7

7.5

12.5

4P

0.65

0.8

1.4

1.5

 

 

 

 

Electric operating device (MD)

External driving operating handle

Automatic release

Thermal electromagnetic type

Thermal electromagnetic type

Thermal electromagnetic type

M11RT thermal adjustable and magnetic adjustable (TAMA) technical data sheet

图片12 

 图片13

 图片14

图片15 

 图片16

Frame current (A)

160

250

400

630

1250

Model

M11RT-160S

M11RT-160H

M11RT-250S

M11RT-250H

M11RT-400S

M11RT-400H

M11RT-630S

M11RT-630H

M11RT-1250S

M11RT-1250H

Pole number

3, 4

3, 4

3, 4

3, 4

3, 4

Rated current (A)

20-25, 25-32, 32-40, 40-50, 50-63,

100-125, 125-160, 160-200, 200-250A

200-250, 250-320,320-400

400-500, 500-630

630-800,800-1250

63-80,80-100, 100-125A, 125-160A

AC400V

AC400V

AC400V

Rated voltage (V)

AC400V

AC400V

AC1000V

AC1000V

AC1000V

Rated insulation voltage (V)

AC1000V

AC1000V

35/25

50/35

35/25

50/35

50/35

65/50

Short-circuit breaking capacity(KA)Icu/Ics

AC400V

25/18

35/25

25/18

35/25

2000

2000

1500

Operating cycle number

Electrical life

3000

3000

4000

4000

4000

Mechanical life

7000

7000

1000

1000

1000

Outline dim(mm) a-b-c-ca

图片18

 

 

 

 

3P

90-155-68-90

90-155-88-115

105-165-68-92

105-165-88-115

140-257-103-155

140-257-103-155

210-275-103-155

4P

120-155-68-90

120-155-88-115

140-165-68-92

140-165-88-115

185-257-103-155

185-257-103-155

280-275-103-155

 

 

 

 

Weight (kg)

3P

1

1.1

1.5

1.7

5.5

5.7

9.5

4P

1.1

1.7

1.9

2.1

7

7.5

12.5

Electric operating device (MD)

External driving

operating handle

Automatic release

Thermal electromagnetic type

Thermal electromagnetic type

M11E Electronic type MCCB technical data sheet

 图片19  图片20  图片21  图片22  图片23

Frame current (A)

160

250

400

630

1250

Model

M11Е-160H

M11Е-250H

M11Е-400H

M11Е-630H

M11Е-1250H

Pole number

3, 4

3, 4

3, 4

3, 4

3, 4

Rated current (A)

16-32, 40-125,80-160

16-32,40-125,80-160,100-250

200-400

200-400,300-630

400-800,800-1250

Rated voltage (V)

AC400V

Rated insulation voltage (V)

AC1000V

Short-circuit breaking capacity(KA)Icu/Ics

AC400V

35/25

35/25

50/35

50/35

65/50

Operating cycle number

Electrical life

1500

1000

1000

1000

1000

Mechanical life

7000

7000

4000

4000

4000

Outline dim(mm) a-b-c-ca

图片24

 

3P

90-155-88-115

105-165-88-115

140-257-103-155

140-257-103-155

210-257-103-155

4P

90-155-88-115

140-165-88-115

185-257-103-155

185-257-103-155

280-257-103-155

 

Weight (kg)

3P

1.8

2.1

5.5

5.7

5.7

4P

2.3

2.6

7

7.5

7.5

Electric operating device (MD)

External driving operating handle

Automatic release

Electronic type

Panel and function description

Intelligent release panel

图片25

Panel adjustment knob as follows in turn

● IR(A) Isd(x IR) Ii(x IR)
● IR: Overload long delay tripping setting current; Isd: Short-circuit short delay tripping setting current;
● Ii: Short-circuit instantaneous tripping setting current;

The rest parameters are set by factory default, or set by remote communication, as follows

● tR: Overload long delay setting time, factory default: 60s;
● tsd: Short-circuit short delay setting time, factory default: 0.1s;
● Ip: Overload pre-alarm setting current, factory default: 0.85*IR;

Intelligent communication port (COM)

1:Power supply input DC24V(+)

6:485B-

2:Power supply input DC24V(-)

7:Closing and opening common terminal of electric operating mechanism

3:485A+

8:Closing and opening common terminal of electric operating mechanism

4:485A+

9:Opening of electric operating mechanism

5:485B-

10:Closing of electric operating mechanism

Panel With Residual Current Protection

图片26

  • Previous:
  • Next:

  • Write your message here and send it to us